NFPA (Fire) 214
Click here to purchase
Codes and standards published by NFPA are displayed as read-only under license from NFPA solely for use within this system. NFPA material may not be downloaded, printed, reproduced, or transferred.
Help protect people and property with the latest requirements from NFPA 214, Standard on Water-Cooling Towers.
Water-cooling towers are essential for fire protection. NFPA 214 presents the updated requirements for fire protection for field-erected and factory-assembled water-cooling towers of combustible construction, or those in which the fill is of combustible material.
NFPA 214 helps experts determine the type and amount of fire protection needed by taking into account the following factors:
- Continuity of operation
- Size and construction of tower
- Type of tower
- Location of tower
- Water supply
- Climate
Designers, installers, inspectors, and maintenance personnel utilize NFPA 214 for fire protection. Code officials depend on this standard for inspection, and facilities managers reference its maintenance chapter to help ensure proper care.(Print, 32 pp., 2021)
References throughout the standard were updated for the 2021 edition to reflect the most current safety documents concerning water-cooling towers, which include the SFPE Engineering Guide for Fire Risk Assessment and the SFPE Handbook of Fire Protection Engineering.
Get the latest updates on fire protection for water-cooling towers by ordering the 2021 edition of NFPA 214, Standard on Water-Cooling Towers, today.
Product Details
- Published:
- 10/25/2020
- ANSI:
- ANSI Approved
- Number of Pages:
- 27
NFPA (Fire) 214
Click here to purchase
Water-cooling towers are a vital aspect of fire protection. NFPA 214 is your source for the latest facts for designers, installers, inspectors, and maintenance personnel.
NFPA 214: Standard on Water-Cooling Towers presents the latest requirements and data on fire protection systems for field-erected and factory-assembled water-cooling towers of combustible construction — or those in which the fill is of combustible material.
This vital Standard helps fire protection designers and engineers work confidently to determine the type and amount of fire protection needed — by taking into account factors such as importance to continuity of operation, size and construction of tower, type of tower, location of tower, water supply, and climate. Code officials depend on NFPA 214 for inspection, and facilities managers reference its maintenance chapter to help ensure proper care.
Chapters address:
- Location of water-cooling towers, including construction materials and fire risk analysis
- Fire protection system design, corrosion protection, hydrant and standpipe protection, water supply, and lightning and earthquake protection
- Electrical equipment and wiring, including installation and overcurrent protection
- Maintenance, with sections on housekeeping, smoking, mechanical inspection, inspection frequency, welding and cutting, access, lockout, and more
Product Details
- Published:
- 12/04/2015
- ISBN(s):
- 9781455913053
- ANSI:
- ANSI Approved
NFPA (Fire) 214
Click here to purchase
NFPA 214: Standard on Water-Cooling Towers provisions help you determine the type and amount of fire protection needed by taking into account factors such as importance to continuity of operation, size and construction of tower, type of tower, location of tower, water supply, and climate.
Product Details
- Published:
- 08/25/2010
- ISBN(s):
- 9781616650704
- ANSI:
- ANSI Approved
- Number of Pages:
- 22