Side Navigation

X

NFPA (Fire) 14

Click here to purchase
Use the revised best practices for standpipe systems in NFPA 14.
Follow the updated rules in the 2010 NFPA 14: Standard for the Installation of Standpipe and Hose Systems and improve fire protection and fire safety. The 2010 edition includes important changes for system designers and installers, including:

* New requirements permitting express mains supplying higher zone standpipes to be designed with pressures in excess of 350 psi (24 bar) in accordance with their materials listings or as approved by the AHJ.
* Clarified requirements regarding standpipe system zones
* New requirements concerning standpipe systems with risers that terminate at different floor levels
* New and revised definitions for standpipe, horizontal standpipe, and express main

This widely used document is essential for system designers and installers and also important for insurance professionals, AHJs, and others.

Product Details

Published:
12/05/2009
ISBN(s):
9780877659204
Number of Pages:
46

NFPA (Fire) 14

Click here to purchase
The best practices for standpipe and hose systems have changed. The 2016 edition of NFPA 14 is vital for fire protection professionals.

Product Details

Published:
12/04/2015
ISBN(s):
9781455912940
Number of Pages:
60

NFPA (Fire) 14

Click here to purchase
An essential resource for improving fire protection and fire safety, the 2019 edition of NFPA 14, Standard for the Installation of Standpipe and Hose Systems has been revised for consistency with the latest version of NFPA 13, Standard for the Installation of Sprinkler Systems and provides the most current requirements for the design, installation, testing, inspections, and maintenance for standpipe and hose systems. (Softbound, 60 pp., 2016)

Product Details

Published:
11/25/2018
ISBN(s):
9781455921393
Number of Pages:
67

NFPA (Fire) 14

Click here to purchase
The best practices for standpipe and hose systems have changed. The 2013 edition of NFPA 14 is vital for fire protection professionals.

Follow the 2013 NFPA 14: Standard for the Installation of Standpipe and Hose Systems to improve fire protection and fire safety. This edition includes important technical changes that give system designers and installers additional guidance and support:

  • Clarified language addresses hose valve locations with respect to horizontal exits
  • New established clearance around hose valve handles helps ensure fire fighters wearing gloves can operate the valve without difficulty.
  • Added requirements for heat tracing and new guidance with respect to “supervised”
  • Clarified travel distance requirements relating to standpipe location throughout a floor area
  • Fully revised requirements for drains and main drains clarify their intended function, purpose, and installation.

Information in NFPA 14 is essential for system designers and installers and also important for insurance professionals, AHJs, and anyone responsible for the operational readiness of standpipe and hose systems.

Product Details

Published:
12/17/2012
ISBN(s):
9781455905690
Number of Pages:
52